-
1 заземляющий контакт
earth contact, grounding contactРусско-английский исловарь по машиностроению и автоматизации производства > заземляющий контакт
-
2 заземление
1) General subject: earth, earthing, ground, earth bonding2) Aviation: electrical ground, power ground3) Engineering: connection to ground, earth terminal, short to ground4) Construction: contact to earth, earthing system, electrical earthing, ground contact, protective conductor5) British English: connection to earth, short to earth6) Railway term: conductive earth7) Automobile industry: grounding9) Oil: earth connection, earth, earthing, ground connection10) Astronautics: Earth grounding, bonding11) Household appliances: earth system, ground system13) Microelectronics: grounding connection14) Network technologies: GND15) Automation: bonding (напр. аппаратуры), earth contact, earthing (см. тж grounding), earthing contact17) Electrochemistry: earth arrangement, ground bed18) oil&gas: electrical grounding19) Electrical engineering: groundbed, PE( protective earthing), earth ground, (power ground) PGND -
3 ток замыкания на землю
ток замыкания на землю
Ток повреждения, проходящий в землю через место замыкания.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
ток замыкания на землю
Электрический ток, протекающий в Землю, открытую и стороннюю проводящие части и защитный проводник при повреждении изоляции токоведущей части.
Примечание – В Международном электротехническом словаре используют термин «ток повреждения на землю».
При повреждении изоляции токоведущей части резко уменьшается сопротивление между этой токоведущей частью, с одной стороны, и Землёй, открытыми, сторонними проводящими частями и защитными проводниками, с другой стороны. В результате этого резко увеличивается величина электрического тока, стекающего с токоведущей части в Землю, а также в проводящие части, соединённые защитными проводниками с заземляющим устройством электроустановки здания и с заземлённой токоведущей частью источника питания. Подобный электрический ток аварийного режима электроустановки здания в нормативной и правовой документации называют током замыкания на землю.
Путь, по которому может протекать ток замыкания на землю, зависит от типа заземления системы. Если произошло повреждение основной изоляции опасной токоведущей части электрооборудования класса I и возникло её замыкание на открытую проводящую часть, то в электроустановке здания, соответствующей типам заземления системы TT и IT, ток замыкания на землю через повреждённую изоляцию протекает из токоведущей части в открытую проводящую часть. Далее из открытой проводящей части по защитному проводнику, главной заземляющей шине, заземляющим проводникам и заземлителю электрический ток протекает в локальную землю. Если электроустановка здания соответствует типам заземления системы TN, преобладающая часть тока замыкания на землю протекает не в локальную землю, а по защитным проводникам и по PEN-проводникам электроустановки здания и низковольтной распределительной электрической сети протекает к заземлённой токоведущей части источника питания.
[] http://www.volt-m.ru/glossary/letter/%D2/view/81/EN
earth fault current
current flowing to earth due to an insulation fault
[IEV number 442-01-23]FR
courant de défaut à la terre
courant qui s'écoule à la terre lors d'un défaut d'isolement
[IEV number 442-01-23]Параллельные тексты EN-RU The earth fault current starts as a localized arc at the point where the insulation has failed; this arc is characterized by a rather modest current level of the order of tens of milliamps. Subsequently, the fault evolves, more or less rapidly, to become a true earth-phase fault. If not rapidly interrupted by protection devices, this fault may end up affecting all the phases, creating a three-phase shortcircuit with earth contact.
[ABB]Ток замыкания на землю возникает в зоне повреждения изоляции в виде локальной дуги. Эта дуга характеризуется относительно небольшим значением тока порядка десятков миллиампер. Со временем зона повреждения изоляции постепенно увеличивается, и образуется однофазное замыкание на землю. Если ток не будет своевременно отключен устройством защиты, то эта неисправность в итоге может затронуть все фазные проводники и привести к трехфазному короткому замыканию на землю.
[Перевод Интент]Therefore, the first consequence of the earth fault current is the damage caused to the plant, whether due to the modest initial arc currents which, because of the difficulty in detection by the overcurrent releases may continue for long periods of time and start a fire, or due to the shortcircuit that develops after the integrity of the entire plant has been jeopardized.
[ABB]Таким образом, ток замыкания на землю может повредить электроустановку. Сначала возникает электрическая дуга с небольшим током, который максимальный расцепитель тока обнаружить не в состоянии, вследствие чего этот ток может протекать длительное время и привести к пожару. Кроме того, может возникнуть короткое замыкание, способное полностью вывести электроустановку из строя.
[Перевод Интент]Another important consequence of the earth fault current involves the danger to persons caused by indirect contact, i.e. following the contact with exposed-conductive-parts that have been energized accidentally due to a decay in the insulation.
[ABB]Другим последствием тока замыкания на землю является опасность косвенного прикосновения, т. е. прикосновения человека к открытым проводящим частям, оказавшимся вследствие повреждения изоляции под напряжением.
[Перевод Интент]Тематики
EN
DE
FR
3.1.1 ток замыкания на землю (earth fault current): Ток, протекающий в землю при повреждении изоляции.
Источник: ГОСТ Р МЭК 60755-2012: Общие требования к защитным устройствам, управляемым дифференциальным (остаточным) током оригинал документа
3.1.1 ток замыкания на землю (earth fault current): Ток, протекающий в землю при повреждении изоляции
Источник: ГОСТ Р 51327.1-2010: Выключатели автоматические, управляемые дифференциальным током, бытового и аналогичного назначения со встроенной защитой от сверхтоков. Часть 1. Общие требования и методы испытаний оригинал документа
Русско-английский словарь нормативно-технической терминологии > ток замыкания на землю
-
4 ток замыкания на землю
ток замыкания на землю
Ток повреждения, проходящий в землю через место замыкания.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
ток замыкания на землю
Электрический ток, протекающий в Землю, открытую и стороннюю проводящие части и защитный проводник при повреждении изоляции токоведущей части.
Примечание – В Международном электротехническом словаре используют термин «ток повреждения на землю».
При повреждении изоляции токоведущей части резко уменьшается сопротивление между этой токоведущей частью, с одной стороны, и Землёй, открытыми, сторонними проводящими частями и защитными проводниками, с другой стороны. В результате этого резко увеличивается величина электрического тока, стекающего с токоведущей части в Землю, а также в проводящие части, соединённые защитными проводниками с заземляющим устройством электроустановки здания и с заземлённой токоведущей частью источника питания. Подобный электрический ток аварийного режима электроустановки здания в нормативной и правовой документации называют током замыкания на землю.
Путь, по которому может протекать ток замыкания на землю, зависит от типа заземления системы. Если произошло повреждение основной изоляции опасной токоведущей части электрооборудования класса I и возникло её замыкание на открытую проводящую часть, то в электроустановке здания, соответствующей типам заземления системы TT и IT, ток замыкания на землю через повреждённую изоляцию протекает из токоведущей части в открытую проводящую часть. Далее из открытой проводящей части по защитному проводнику, главной заземляющей шине, заземляющим проводникам и заземлителю электрический ток протекает в локальную землю. Если электроустановка здания соответствует типам заземления системы TN, преобладающая часть тока замыкания на землю протекает не в локальную землю, а по защитным проводникам и по PEN-проводникам электроустановки здания и низковольтной распределительной электрической сети протекает к заземлённой токоведущей части источника питания.
[] http://www.volt-m.ru/glossary/letter/%D2/view/81/EN
earth fault current
current flowing to earth due to an insulation fault
[IEV number 442-01-23]FR
courant de défaut à la terre
courant qui s'écoule à la terre lors d'un défaut d'isolement
[IEV number 442-01-23]Параллельные тексты EN-RU The earth fault current starts as a localized arc at the point where the insulation has failed; this arc is characterized by a rather modest current level of the order of tens of milliamps. Subsequently, the fault evolves, more or less rapidly, to become a true earth-phase fault. If not rapidly interrupted by protection devices, this fault may end up affecting all the phases, creating a three-phase shortcircuit with earth contact.
[ABB]Ток замыкания на землю возникает в зоне повреждения изоляции в виде локальной дуги. Эта дуга характеризуется относительно небольшим значением тока порядка десятков миллиампер. Со временем зона повреждения изоляции постепенно увеличивается, и образуется однофазное замыкание на землю. Если ток не будет своевременно отключен устройством защиты, то эта неисправность в итоге может затронуть все фазные проводники и привести к трехфазному короткому замыканию на землю.
[Перевод Интент]Therefore, the first consequence of the earth fault current is the damage caused to the plant, whether due to the modest initial arc currents which, because of the difficulty in detection by the overcurrent releases may continue for long periods of time and start a fire, or due to the shortcircuit that develops after the integrity of the entire plant has been jeopardized.
[ABB]Таким образом, ток замыкания на землю может повредить электроустановку. Сначала возникает электрическая дуга с небольшим током, который максимальный расцепитель тока обнаружить не в состоянии, вследствие чего этот ток может протекать длительное время и привести к пожару. Кроме того, может возникнуть короткое замыкание, способное полностью вывести электроустановку из строя.
[Перевод Интент]Another important consequence of the earth fault current involves the danger to persons caused by indirect contact, i.e. following the contact with exposed-conductive-parts that have been energized accidentally due to a decay in the insulation.
[ABB]Другим последствием тока замыкания на землю является опасность косвенного прикосновения, т. е. прикосновения человека к открытым проводящим частям, оказавшимся вследствие повреждения изоляции под напряжением.
[Перевод Интент]Тематики
EN
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > ток замыкания на землю
-
5 ток замыкания на землю
ток замыкания на землю
Ток повреждения, проходящий в землю через место замыкания.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
ток замыкания на землю
Электрический ток, протекающий в Землю, открытую и стороннюю проводящие части и защитный проводник при повреждении изоляции токоведущей части.
Примечание – В Международном электротехническом словаре используют термин «ток повреждения на землю».
При повреждении изоляции токоведущей части резко уменьшается сопротивление между этой токоведущей частью, с одной стороны, и Землёй, открытыми, сторонними проводящими частями и защитными проводниками, с другой стороны. В результате этого резко увеличивается величина электрического тока, стекающего с токоведущей части в Землю, а также в проводящие части, соединённые защитными проводниками с заземляющим устройством электроустановки здания и с заземлённой токоведущей частью источника питания. Подобный электрический ток аварийного режима электроустановки здания в нормативной и правовой документации называют током замыкания на землю.
Путь, по которому может протекать ток замыкания на землю, зависит от типа заземления системы. Если произошло повреждение основной изоляции опасной токоведущей части электрооборудования класса I и возникло её замыкание на открытую проводящую часть, то в электроустановке здания, соответствующей типам заземления системы TT и IT, ток замыкания на землю через повреждённую изоляцию протекает из токоведущей части в открытую проводящую часть. Далее из открытой проводящей части по защитному проводнику, главной заземляющей шине, заземляющим проводникам и заземлителю электрический ток протекает в локальную землю. Если электроустановка здания соответствует типам заземления системы TN, преобладающая часть тока замыкания на землю протекает не в локальную землю, а по защитным проводникам и по PEN-проводникам электроустановки здания и низковольтной распределительной электрической сети протекает к заземлённой токоведущей части источника питания.
[] http://www.volt-m.ru/glossary/letter/%D2/view/81/EN
earth fault current
current flowing to earth due to an insulation fault
[IEV number 442-01-23]FR
courant de défaut à la terre
courant qui s'écoule à la terre lors d'un défaut d'isolement
[IEV number 442-01-23]Параллельные тексты EN-RU The earth fault current starts as a localized arc at the point where the insulation has failed; this arc is characterized by a rather modest current level of the order of tens of milliamps. Subsequently, the fault evolves, more or less rapidly, to become a true earth-phase fault. If not rapidly interrupted by protection devices, this fault may end up affecting all the phases, creating a three-phase shortcircuit with earth contact.
[ABB]Ток замыкания на землю возникает в зоне повреждения изоляции в виде локальной дуги. Эта дуга характеризуется относительно небольшим значением тока порядка десятков миллиампер. Со временем зона повреждения изоляции постепенно увеличивается, и образуется однофазное замыкание на землю. Если ток не будет своевременно отключен устройством защиты, то эта неисправность в итоге может затронуть все фазные проводники и привести к трехфазному короткому замыканию на землю.
[Перевод Интент]Therefore, the first consequence of the earth fault current is the damage caused to the plant, whether due to the modest initial arc currents which, because of the difficulty in detection by the overcurrent releases may continue for long periods of time and start a fire, or due to the shortcircuit that develops after the integrity of the entire plant has been jeopardized.
[ABB]Таким образом, ток замыкания на землю может повредить электроустановку. Сначала возникает электрическая дуга с небольшим током, который максимальный расцепитель тока обнаружить не в состоянии, вследствие чего этот ток может протекать длительное время и привести к пожару. Кроме того, может возникнуть короткое замыкание, способное полностью вывести электроустановку из строя.
[Перевод Интент]Another important consequence of the earth fault current involves the danger to persons caused by indirect contact, i.e. following the contact with exposed-conductive-parts that have been energized accidentally due to a decay in the insulation.
[ABB]Другим последствием тока замыкания на землю является опасность косвенного прикосновения, т. е. прикосновения человека к открытым проводящим частям, оказавшимся вследствие повреждения изоляции под напряжением.
[Перевод Интент]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > ток замыкания на землю
-
6 заземляющий контакт
1) Engineering: grounding terminal2) Automobile industry: ground contact3) Atomic energy: grounding stud4) Automation: earth contact, earthing contact, grounding contact5) Electrical engineering: earthing block, earthing boss, grounding block, grounding bossУниверсальный русско-английский словарь > заземляющий контакт
-
7 заземление
(напр. аппаратуры) bonding, earth connection, ground connection, earth contact, earthing, electrical ground, ground, groundingРусско-английский исловарь по машиностроению и автоматизации производства > заземление
-
8 земля (в электроустановках)
земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой не обязательно равен нулю.
[ ГОСТ Р МЭК 60050-195-2005]
(локальная) земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой необязательно равен нулю.
[ ГОСТ Р МЭК 60050-826-2009]
Вблизи заземлителя потенциал может быть не равен нулю
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]
земля
Проводящая масса земли, электрический потенциал которой в любой точке условно принимают равным нулю
[МЭС 826-04-01].
[ ГОСТ Р 61557-1-2006]EN
(local) earth
part of the Earth which is in electric contact with an earth electrode and the electric potential of which is not necessarily equal to zero
[IEV number 195-01-03]FR
terre (locale)
partie de la Terre en contact électrique avec une prise de terre, et dont le potentiel électrique n'est pas nécessairement égal à zéro
[IEV number 195-01-03]Тематики
Синонимы
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > земля (в электроустановках)
-
9 боковой заземляющий контакт
Русско-английский словарь нормативно-технической терминологии > боковой заземляющий контакт
-
10 контактное сопротивление
противостоять, оказывать сопротивление — to offer resistance
Русско-английский новый политехнический словарь > контактное сопротивление
-
11 заземляющий электрод
заземляющий электрод
Проводящая часть, находящаяся в электрическом контакте с Землей непосредственно или через промежуточную проводящую среду, например бетон.
[ ГОСТ Р МЭК 60050-195-2005]
заземляющий электрод
Проводящая часть, которая может быть погружена в землю или в специальную проводящую среду, например бетон или уголь, и находящаяся в электрическом контакте с Землей.
[ ГОСТ Р МЭК 60050-826-2009]
заземляющий электрод
Проводящая часть или группа проводящих частей, находящиеся в непосредственном контакте с землей и обеспечивающие электрическое соединение с ней.
[МЭС 826-04-02]
[ ГОСТ Р 61557-1-2006]
заземляющий электрод (заземлитель)
проводящая часть, находящаяся в электрическом контакте с Землёй непосредственно или через промежуточную проводящую среду, например, бетон
[IEV number 461-06-18]EN
earth electrode
conductive part, which may be embedded in a specific conductive medium, e.g. concrete or coke, in electric contact with the Earth
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
earth electrode
ground electrode (USA)
conductor or group of conductors in intimate contact with and providing an electrical connection to earth
Source: 604-04-03
[IEV number 461-06-18]FR
électrode de terre
partie conductrice pouvant être incorporée dans un milieu conducteur particulier, par exemple béton ou coke, en contact électrique avec la Terre
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
électrode de terre
prise de terre
conducteur ou ensemble de conducteurs groupés, en contact intime avec le sol, destinés à établir une liaison électrique avec celui-ci
Source: 604-04-03
[IEV number 461-06-18]Рис. ABB
Система ТТ
1 - заземляемая точка;
2 - заземляющий проводник (earthing conductor);
3 - заземлитель ( заземляющий электрод);
4 - открытая проводящая часть (exposed-conductive-part);
5 - заземляющее устройство (earthing arrangement) электроустановки;
6 - заземляющее устройство нейтрали;
7 - источник питания;
8 - однофазная нагрузка;
RA - сопротивление заземляющего устройства электроустановки;
RB - сопротивление заземляющего устройства нейтрали;Тематики
Синонимы
EN
DE
FR
заземляющий электрод (earth electrode): Проводящая часть, которая может быть погружена в землю или в специальную проводящую среду, например бетон или уголь, и находящаяся в электрическом контакте с землей.
[ ГОСТ Р МЭК 60050-826-2009, статья 826-13-05]
Источник: ГОСТ Р 54127-1-2010: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
3.1.19 заземляющий электрод (earth electrode): Проводящая часть или группа проводящих частей, находящиеся в непосредственном контакте с землей и обеспечивающие электрическое соединение с ней [МЭС 826-04-02].
Источник: ГОСТ Р МЭК 61557-1-2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > заземляющий электрод
-
12 заземляющий электрод
заземляющий электрод
Проводящая часть, находящаяся в электрическом контакте с Землей непосредственно или через промежуточную проводящую среду, например бетон.
[ ГОСТ Р МЭК 60050-195-2005]
заземляющий электрод
Проводящая часть, которая может быть погружена в землю или в специальную проводящую среду, например бетон или уголь, и находящаяся в электрическом контакте с Землей.
[ ГОСТ Р МЭК 60050-826-2009]
заземляющий электрод
Проводящая часть или группа проводящих частей, находящиеся в непосредственном контакте с землей и обеспечивающие электрическое соединение с ней.
[МЭС 826-04-02]
[ ГОСТ Р 61557-1-2006]
заземляющий электрод (заземлитель)
проводящая часть, находящаяся в электрическом контакте с Землёй непосредственно или через промежуточную проводящую среду, например, бетон
[IEV number 461-06-18]EN
earth electrode
conductive part, which may be embedded in a specific conductive medium, e.g. concrete or coke, in electric contact with the Earth
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
earth electrode
ground electrode (USA)
conductor or group of conductors in intimate contact with and providing an electrical connection to earth
Source: 604-04-03
[IEV number 461-06-18]FR
électrode de terre
partie conductrice pouvant être incorporée dans un milieu conducteur particulier, par exemple béton ou coke, en contact électrique avec la Terre
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
électrode de terre
prise de terre
conducteur ou ensemble de conducteurs groupés, en contact intime avec le sol, destinés à établir une liaison électrique avec celui-ci
Source: 604-04-03
[IEV number 461-06-18]Рис. ABB
Система ТТ
1 - заземляемая точка;
2 - заземляющий проводник (earthing conductor);
3 - заземлитель ( заземляющий электрод);
4 - открытая проводящая часть (exposed-conductive-part);
5 - заземляющее устройство (earthing arrangement) электроустановки;
6 - заземляющее устройство нейтрали;
7 - источник питания;
8 - однофазная нагрузка;
RA - сопротивление заземляющего устройства электроустановки;
RB - сопротивление заземляющего устройства нейтрали;Тематики
Синонимы
EN
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > заземляющий электрод
-
13 заземляющий электрод
заземляющий электрод
Проводящая часть, находящаяся в электрическом контакте с Землей непосредственно или через промежуточную проводящую среду, например бетон.
[ ГОСТ Р МЭК 60050-195-2005]
заземляющий электрод
Проводящая часть, которая может быть погружена в землю или в специальную проводящую среду, например бетон или уголь, и находящаяся в электрическом контакте с Землей.
[ ГОСТ Р МЭК 60050-826-2009]
заземляющий электрод
Проводящая часть или группа проводящих частей, находящиеся в непосредственном контакте с землей и обеспечивающие электрическое соединение с ней.
[МЭС 826-04-02]
[ ГОСТ Р 61557-1-2006]
заземляющий электрод (заземлитель)
проводящая часть, находящаяся в электрическом контакте с Землёй непосредственно или через промежуточную проводящую среду, например, бетон
[IEV number 461-06-18]EN
earth electrode
conductive part, which may be embedded in a specific conductive medium, e.g. concrete or coke, in electric contact with the Earth
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
earth electrode
ground electrode (USA)
conductor or group of conductors in intimate contact with and providing an electrical connection to earth
Source: 604-04-03
[IEV number 461-06-18]FR
électrode de terre
partie conductrice pouvant être incorporée dans un milieu conducteur particulier, par exemple béton ou coke, en contact électrique avec la Terre
Source: 461-06-18 MOD, 604-04-03 MOD, 826-04-02 MOD
[IEV number 195-02-01]
électrode de terre
prise de terre
conducteur ou ensemble de conducteurs groupés, en contact intime avec le sol, destinés à établir une liaison électrique avec celui-ci
Source: 604-04-03
[IEV number 461-06-18]Рис. ABB
Система ТТ
1 - заземляемая точка;
2 - заземляющий проводник (earthing conductor);
3 - заземлитель ( заземляющий электрод);
4 - открытая проводящая часть (exposed-conductive-part);
5 - заземляющее устройство (earthing arrangement) электроустановки;
6 - заземляющее устройство нейтрали;
7 - источник питания;
8 - однофазная нагрузка;
RA - сопротивление заземляющего устройства электроустановки;
RB - сопротивление заземляющего устройства нейтрали;Тематики
Синонимы
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > заземляющий электрод
-
14 замыкание на корпус
замыкание на корпус
Электрическое соединение токоведущей части с открытой проводящей частью.
[ ГОСТ Р 50669-94]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > замыкание на корпус
-
15 земля (в электроустановках)
земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой не обязательно равен нулю.
[ ГОСТ Р МЭК 60050-195-2005]
(локальная) земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой необязательно равен нулю.
[ ГОСТ Р МЭК 60050-826-2009]
Вблизи заземлителя потенциал может быть не равен нулю
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]
земля
Проводящая масса земли, электрический потенциал которой в любой точке условно принимают равным нулю
[МЭС 826-04-01].
[ ГОСТ Р 61557-1-2006]EN
(local) earth
part of the Earth which is in electric contact with an earth electrode and the electric potential of which is not necessarily equal to zero
[IEV number 195-01-03]FR
terre (locale)
partie de la Terre en contact électrique avec une prise de terre, et dont le potentiel électrique n'est pas nécessairement égal à zéro
[IEV number 195-01-03]Тематики
Синонимы
EN
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > земля (в электроустановках)
-
16 земля (в электроустановках)
земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой не обязательно равен нулю.
[ ГОСТ Р МЭК 60050-195-2005]
(локальная) земля
Часть Земли, которая находится в электрическом контакте с заземлителем и электрический потенциал которой необязательно равен нулю.
[ ГОСТ Р МЭК 60050-826-2009]
Вблизи заземлителя потенциал может быть не равен нулю
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]
земля
Проводящая масса земли, электрический потенциал которой в любой точке условно принимают равным нулю
[МЭС 826-04-01].
[ ГОСТ Р 61557-1-2006]EN
(local) earth
part of the Earth which is in electric contact with an earth electrode and the electric potential of which is not necessarily equal to zero
[IEV number 195-01-03]FR
terre (locale)
partie de la Terre en contact électrique avec une prise de terre, et dont le potentiel électrique n'est pas nécessairement égal à zéro
[IEV number 195-01-03]Тематики
Синонимы
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > земля (в электроустановках)
-
17 замыкание на корпус
1) American: ground fault2) Engineering: body contact, chassis fault, connection to the frame, contact to frame fault, contact to the frame, fault to frame, fault to the frame, ironwork fault, frame fault3) Construction: connection to frame, frame connection4) British English: earth fault5) Electronics: frame ground6) Oil: voltage by failure to frame8) Electrical engineering: contact to frameУниверсальный русско-английский словарь > замыкание на корпус
-
18 защита от замыкания на землю
- protection against ground-fault
- protection against ground fault
- protection against earth fault
- ground-fault protection
- earth-fault protection
- earth fault protection
защита от замыканий на землю
Защита, предназначенная срабатывать при замыканиях на землю в энергосистеме.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
earth-fault protection
ground-fault protection (US)
protection intended to operate for power system earth faults
[IEV ref 448-14-28]FR
protection de défaut à la terre
protection destinée à fonctionner en cas de défaut à la terre dans le réseau d'énergie
[IEV ref 448-14-28]Параллельные тексты EN-RU
The earth fault, caused by an insulation loss between a live conductor and an exposed conductive part, represents a plant engineering problem which may cause damage to the electrical installations and above all may jeopardize people; as a matter of fact, people could get in touch with an exposed-conductive-part not normally live but which, due to the fault, might have a dangerous potential to ground.
The scope of this technical paper is providing the reader with the necessary information about the main normative aspects regarding protection against earth fault and indirect contact, clarifying the relevant problems and illustrating the solution proposed by ABB SACE
[ABB]Замыкания на землю, вызванные повреждением изоляции между токоведущим проводником и открытой проводящей частью, представляют определенную проблему при эксплуатации электроустановок, поскольку такие неисправности могут привести к выходу электрооборудования из строя и, кроме того, подвергают людей опасности поражения электрическим током. Это объясняется тем, что человек может прикоснуться к открытой проводящей части, которая в нормальных условиях не находится под напряжением, но из-за повреждения изоляции приобретает опасный потенциал относительно земли.
В рамках данного технического документа читателю будет предоставлена вся необходимая информация об основных нормативных аспектах, касающихся обеспечения защиты от замыкания на землю и защиты при косвенном прикосновении, при этом будут подробно рассмотрены существующие проблемы и описаны решения, предлагаемые ABB SACE.
[Перевод Интент]Тематики
- выключатель автоматический
- расцепитель, тепловое реле
- релейная защита
- электробезопасность
EN
- earth fault protection
- earth-fault protection
- ground-fault protection
- protection against earth fault
- protection against ground fault
- protection against ground-fault
DE
- Erdkurzschlussschutz, m
FR
Русско-английский словарь нормативно-технической терминологии > защита от замыкания на землю
-
19 замыкание на землю
1) Engineering: earth, earth connection, earthing, fault to ground, ground connection, ground short circuit (короткое), grounding, grounding connection, short to ground, ( нулевой потенциал) shorted low2) Construction: ground3) British English: fault to earth, short to earth4) Railway term: contact to earth5) Telecommunications: earth fault6) Electronics: earth-fault, ground fault7) Automation: intermittent earthУниверсальный русско-английский словарь > замыкание на землю
-
20 защита от замыкания на землю
- Erdkurzschlussschutz, m
защита от замыканий на землю
Защита, предназначенная срабатывать при замыканиях на землю в энергосистеме.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
earth-fault protection
ground-fault protection (US)
protection intended to operate for power system earth faults
[IEV ref 448-14-28]FR
protection de défaut à la terre
protection destinée à fonctionner en cas de défaut à la terre dans le réseau d'énergie
[IEV ref 448-14-28]Параллельные тексты EN-RU
The earth fault, caused by an insulation loss between a live conductor and an exposed conductive part, represents a plant engineering problem which may cause damage to the electrical installations and above all may jeopardize people; as a matter of fact, people could get in touch with an exposed-conductive-part not normally live but which, due to the fault, might have a dangerous potential to ground.
The scope of this technical paper is providing the reader with the necessary information about the main normative aspects regarding protection against earth fault and indirect contact, clarifying the relevant problems and illustrating the solution proposed by ABB SACE
[ABB]Замыкания на землю, вызванные повреждением изоляции между токоведущим проводником и открытой проводящей частью, представляют определенную проблему при эксплуатации электроустановок, поскольку такие неисправности могут привести к выходу электрооборудования из строя и, кроме того, подвергают людей опасности поражения электрическим током. Это объясняется тем, что человек может прикоснуться к открытой проводящей части, которая в нормальных условиях не находится под напряжением, но из-за повреждения изоляции приобретает опасный потенциал относительно земли.
В рамках данного технического документа читателю будет предоставлена вся необходимая информация об основных нормативных аспектах, касающихся обеспечения защиты от замыкания на землю и защиты при косвенном прикосновении, при этом будут подробно рассмотрены существующие проблемы и описаны решения, предлагаемые ABB SACE.
[Перевод Интент]Тематики
- выключатель автоматический
- расцепитель, тепловое реле
- релейная защита
- электробезопасность
EN
- earth fault protection
- earth-fault protection
- ground-fault protection
- protection against earth fault
- protection against ground fault
- protection against ground-fault
DE
- Erdkurzschlussschutz, m
FR
Русско-немецкий словарь нормативно-технической терминологии > защита от замыкания на землю
См. также в других словарях:
partial earth contact — dalinis įžemėjimas statusas T sritis radioelektronika atitikmenys: angl. partial earth contact vok. teiweiser Erdschluß, m; unvollkommener Erdschluß, m rus. частичное замыкание на землю, n pranc. mise à la terre partielle, f … Radioelektronikos terminų žodynas
Earth in science fiction — Earth An overwhelming majority of fiction is set on or features the Earth. However, authors of speculative fiction novels and writers and directors of science fiction film deal with Earth quite differently from authors of conventional fiction.… … Wikipedia
Contact (film) — Contact Directed by Robert Zemeckis Produced by Robert Zemeckis Steve Starkey … Wikipedia
Contact (novel) — Contact … Wikipedia
Earth sheltering — is the architectural practice of using earth against building walls for external thermal mass, to reduce heat loss, and to easily maintain a steady indoor air temperature. Earth sheltering is popular in modern times among advocates of passive… … Wikipedia
Earth science — (also known as geoscience, the geosciences or the Earth Sciences), is an all embracing term for the sciences related to the planet Earth [ [http://wordnet.princeton.edu/perl/webwn?s=earth%20science Wordnet Search: Earth science] ] . It is… … Wikipedia
Contact Dance — Contact Dance, or Contact Improvisation ( Contact Improv ), is an emerging dance art that can be done solo (in contact with the self, the ground, an object, etc...), yet usually is improvised with others generally one partner, sometimes with many … Wikipedia
Earth Defense Force 2017 — North American cover art Developer(s) Sandlot Distributor … Wikipedia
Earth Island Institute — logo. The Earth Island Institute was founded in 1982 by environmentalist David Brower.[1] It organizes and encourages activism around environmental issues and provides public education. Funding comes from individual members and supporting… … Wikipedia
Earth's Children — is a series of historical fiction novels written by Jean M. Auel. There are five novels in the series so far and a sixth is being written. Auel has mentioned in recent interviews that she now believes she will write a seventh novel, which will be … Wikipedia
Earth in fiction — An overwhelming majority of fiction is set on or features the Earth. However, authors of speculative fiction novels and writers and directors of science fiction film deal with Earth quite differently than authors of conventional fiction. Unbound… … Wikipedia